Example 4.3 — Activity cliffs: only the ones measured in the same patent

Conversation

👤 User

Find the activity cliffs on menin, but only count a pair when both compounds were measured in the same patent — I don't want to compare two labs' assays. Check the assay conditions where they are recorded.


🧠 Assistant

Among the 928 compounds with an exact IC50 against human menin (target 6958, O00255), activity_cliffs finds 273 pairs at Tanimoto ≥ 0.85 that differ by at least 100-fold. Reading each pair inside a single document instead of across the database changes the answer substantially:

After checking the source of both values Pairs
One document reports both compounds, and the gap is still ≥ 100-fold there 183
One document reports both, but the gap shrinks below 100-fold when read there 51
No document reports both: the two values come from different places 39

So a third of the list does not survive the rule, and the survivors are not spread evenly: 168 of the 183 sit inside one patent and 15 inside one paper. By document (each pair counted once, under the document where its gap is larger): US12473295-B2 97, US10899738-B2 51, US20240335431-A1 16, US11045448-B2 4, and the papers PMID 23244744 10 and PMID 31244110 5. Two pairs are reported in both US10899738-B2 and PMID 31244110, with a gap of at least 100-fold in each.

The 90 that were thrown out have a single main cause: 85 of them are one disagreement between two documents of the same patent family. Three entries are the entire contribution of US20240261292-A1 (2024) to this target: one compound reported at 0.09 and 0.11 nM (measured twice), one named "oxalate" at 0.098 nM, and one at 0.18 nM. Two of the compounds reappear in US12473295-B2 (2025), the first at 80 and 110 nM and the last at 90, 98 and 180 nM, and the "oxalate" entry is a duplicate of the last, its SMILES character-for-character identical. Look at the digits: 0.11 against 110, 0.098 against 98, 0.18 against 180. The 2024 numbers are the 2025 numbers divided by exactly 1,000, and they sit below every one of the 201 compounds' values in the 2025 patent (smallest 33 nM). Both documents give the same written protocol (a terbium-labelled menin / FITC-peptide HTRF competition), so nothing in the recorded conditions explains a gap of 500 to 1,000-fold, and a unit slip in one document is the likelier explanation than biology. That is an inference from the pattern, not something the database states: the raw values are recorded as 0.110, 0.090, 0.098 and 0.180 with the unit nM. Either way the rule is right to refuse the comparison. Of the other 5 discarded pairs, 4 pair a PMID 31244110 value with a US10899738-B2 one that has no document in common, and one is 95 against 9,450 nM inside US12473295-B2, 99.5-fold, just under the threshold.

Why the rule is not the same as what the tool reports. activity_cliffs ranks each compound by its most potent exact value anywhere in the database, which is the right default, but it means the two halves of a pair can come from two different labs. Here that is not a hypothetical: the pair at the top of the raw output is 28,000-fold (0.098 nM against 2,750 nM) and its two values come from two different patents, the 2024 one and the 2025 one. The check is one SQL query: list every (compound, source) value for the compounds in the cliff list, keep the pairs with a source in common, and recompute the difference from that source's own two numbers.

What the conditions say. For the two pairs in the figure the check is clean, and it is worth being precise about what "checked" means here:

The survivors, and what they are made of. 40 of the 183 have identical fingerprints (sali is null because the structural distance is zero), and on this target that almost always means a configuration: 16 of them in US10899738-B2, 12 in US20240335431-A1, 10 in US12473295-B2, 2 in US11045448-B2. The rest are small constitutional changes. The figure shows one of each kind. Its four compounds come from two different chemotypes, so the grid's alignment is on the 8-atom fragment they all share (a fluorophenyl and the carbon on it), not on a real common core; read each pair on its own.

US10899738-B2 makes the stereochemical point repeatedly: its cyclopentyl esters come as a pair of enantiomers, labelled rac-(1S,2R) and rac-(1R,2S), and in the two series I read the first is 700 to 1,100-fold the more potent: 13 against 13,800 nM for the acetate, 237 against 164,600 nM for the isobutyrate.

Two things the rule does not fix. First, nearly every value here is a single measurement (both sides single in 173 of the 183 pairs), so "same patent" removes the cross-lab problem but not a single mistyped number, and the 2024 patent just showed what one looks like. Second, the largest surviving cliff, 16 nM against 923,130 nM in US10899738-B2 (57,000-fold), changes two things at once, the aryl group (3-fluorophenyl to 3-trifluoromethylphenyl) as well as the configuration, so it is not a clean one-change pair however well measured it is. Cliffs at the top of a list are worth reading individually before they are worth believing.

How this was answered

Try next

Example 4.2 is the other way of reading the same data: one substituent change at a time, aggregated over a whole target.

Two menin cliffs, each measured inside one patent

Each row is one pair, both values from the same document and the same assay. Top: one patent's two separated isomers, which differ only at the carbon bearing the nitrile. Bottom: another patent's tail group, a basic amine against the alcohol that replaces it.

US11045448, (S) isomer

the benzylic centre next to the nitrile · BDBM506342 · US11045448-B2 (2021)

CNC(=O)O[C@H]1CCC[C@@H]1[C@@](C#N)(C1CCN(CC2CN(C2)c2ccc(cc2)S(=O)(=O)c2ccc(NC(=O)C=C)cc2)CC1)c1cccc(F)c1 |r|

  • Menin2 nM IC50one value

US11045448, (R) isomer

the same molecule, that centre inverted · BDBM506343 · US11045448-B2 (2021)

CNC(=O)O[C@H]1CCC[C@@H]1[C@](C#N)(C1CCN(CC2CN(C2)c2ccc(cc2)S(=O)(=O)c2ccc(NC(=O)C=C)cc2)CC1)c1cccc(F)c1 |r|

  • Menin2,200 nM IC50one value

US12473295, Compound 122

basic amine on the tail · BDBM787682 · US12473295-B2 (2025)

CCN(C(=O)c1cc(F)ccc1Oc1nncnc1N1CCC2(C1)CN([C@H](CCCN(C)C(C)C)C(C)C)C2)C(C)C

  • Menin65 nM IC50one value

US12473295, Compound 215

the same tail ending in a plain alcohol · BDBM787729 · US12473295-B2 (2025)

CCN(C(=O)c1cc(F)ccc1Oc1nncnc1N1CCC2(C1)CN([C@@H](CCO)C(C)C)C2)C(C)C

  • Menin88,800 nM IC50one value

shared coreIC50thin evidenceBar length: log scale, 100000 nM (empty) to 1 nM (full)

👤 User

How much does BindingDB actually record about the conditions? Can I always do this?


🧠 Assistant

Enough to do this on most targets, as long as you accept that "the conditions" usually means a block of prose rather than two numeric columns. Over every exact Ki, Kd, IC50 and EC50 value in nM:

Source Values Sources pH recorded Temperature recorded Assay name
Article (PMID) 1,454,575 45,157 2.9% 2.6% 98.4%
Patent 1,062,387 8,680 13.0% 12.2% 99.0%
PubChem assay 72,558 663 3.8% 5.8% 92.9%
D3R challenge set 2,659 24 3.5% 0.0% 100%

So the numeric columns are the exception. ph and temp_k are populated for roughly one value in eight from patents and one in thirty-five from papers, and, against intuition, patents are the better-curated source for them, not the worse. On menin they are empty for all 988 rows, which is why the previous answer leaned on the assay text instead: US12473295-B2 states pH 7.5 in its protocol, and that pH never reaches the ph column.

What is almost always there is assay_name, on 98 to 99% of values, and behind it the assay table, keyed by entryid, which carries the full protocol paragraph: buffer, probe, peptide, incubation, plate format, often the temperature in words ("ambient"). That is the layer to read when a comparison matters. activity joins to it on entryid, and one query per document is enough.

"Same patent" is a good proxy for "same assay", but not a perfect one. Of the 8,680 patents with exact values, 6,970 report everything under a single assay name; 1,255 use two, 272 three, 106 four, 30 five, 33 use six or more, and 14 have none recorded. So about one patent in five mixes formats, typically a biochemical assay and a cell assay in the same document, whose IC50s belong in different columns entirely. The robust rule is therefore two conditions, not one: same source_id and same assay_name. On menin that distinction changes nothing for the patents behind the answer above: US12473295-B2, US10899738-B2, US20240335431-A1 and US11045448-B2 each use one assay name. One of the two papers does not: PMID 31244110 reports two assay names on menin, but the nine compounds in its five surviving pairs were all measured under the same one, so those pairs stand. On a patent with a biochemical and a cellular readout the second condition would change everything.

What this never gives you, on any target. The same patent is not the same plate, the same day or the same protein batch: a patent's table is often assembled over several years of a programme. And a document reporting one assay name can still report values measured in two different laboratories. Within-document comparison removes the largest and most systematic source of noise; it does not turn a database into a single experiment.

A practical order to check things in, cheapest first:

  1. source_id: do both numbers come from one document at all? (One SQL query, as in the first answer.)
  2. assay_name: is it the same assay within that document?
  3. The assay table's description: what was actually done, and does the text name a pH, a temperature, a probe concentration?
  4. ph and temp_k: use them when present; do not design a workflow that depends on them.
  5. The number of measurements behind each side: n_measurements in the SAR tools, or get_activity for the individual rows. A cliff where both sides are single values is a hypothesis, however well sourced.

How this was answered

Try next

Example 3.4 drills into a single measurement end to end: value, assay, conditions, citation.