👤 User
Is the fluorine effect target-specific? Compare what adding a fluorine, a methyl and a chlorine do across a kinase, a protease, a hydrolase, a metalloenzyme, a GPCR, an ion channel and a nuclear receptor — and only count a pair when both compounds were measured in the same patent or paper.
🧠 Assistant
No, and the rule does not change that answer, which is itself worth knowing. Across a kinase, a protease, a hydrolase, a metalloenzyme, a GPCR, an ion channel and a nuclear receptor, these three changes make 1,686 matched pairs, and 1,584 of them (94%) have a patent or paper that reports both compounds under one assay name. Read inside those documents, a fluorine and a methyl still do essentially nothing at the median, everywhere; a chlorine does one specific thing on one target (and a second, softer one on another).
| Target (class · type) | Fluorine | Methyl | Chlorine |
|---|---|---|---|
| EGFR (kinase · IC50) | 0.00 (60) | 0.00 (82) | +0.04 (14) |
| BACE1 (aspartyl protease · IC50) | +0.09 (192) | −0.02 (109) | −0.11 (16) |
| AChE (serine hydrolase · IC50) | +0.21 (26) | −0.02 (99) | +0.30 (107) |
| CA II (zinc metalloenzyme · Ki) | +0.02 (32) | +0.01 (78) | 0.00 (51) |
| Adenosine A2A (GPCR · Ki) | 0.00 (91) | +0.02 (123) | 0.00 (21) |
| hERG (ion channel · IC50) | 0.00 (91) | +0.08 (114) | +0.56 (29) |
| ROR-γ (nuclear receptor · IC50) | 0.00 (97) | −0.05 (104) | +0.05 (48) |
Median change in potency in log units, over the pairs that survive the check; the count is in brackets. The figure below shows every pair behind these numbers, with the unverifiable ones in grey.
The flat result is robust. Across all seven targets the fluorine median over all pairs is 0.00 as the database reports it and +0.01 when the rule is applied, and the methyl median stays at 0.00. Whatever a fluorine is worth in your series, the protein class does not predict it, and this is not an artefact of mixing laboratories: it survives when every pair is read from one table.
What the rule changes is the tails, not the middle. Counting pairs that move potency by more than tenfold in either direction:
| Pairs | As the database reports them | Read inside one document |
|---|---|---|
| Fluorine (638 → 589 checked) | 31 | 16 |
| Methyl (744 → 709) | 39 | 30 |
| Chlorine (304 → 286) | 43 | 40 |
About half the dramatic fluorine results disappear, and the worst of them go first: the most negative fluorine pair in the whole set, −3.05, a fluorine apparently costing a thousandfold, was one compound's best value in one paper set against another compound's best value in another. Read inside documents, nothing below −1.48 survives. The discarded pairs are not a random sample either: they lean positive (median +0.11, 63% improved, against 0.00 and 48% for the checked ones, on the database-wide numbers) and 6 of the 31 tenfold-plus fluorine moves sit in the 8% of fluorine pairs the rule throws away.
AChE is where this bites. It is the only target where the check fails often: 10 of its 36 fluorine pairs have no shared document, and those 10 carry 5 of the 11 tenfold-plus moves. Its ligands come almost entirely from small academic papers (only one of its 125 checked fluorine and methyl pairs sits in a patent), and the same compound measured in two of those papers is the classic source of a spurious effect. After the check its fluorine median rises from +0.08 to +0.21 on 26 pairs, a cleaner number, but one you should not lean on.
The chlorine column is the finding that survives everything. On hERG, 29 of 31 chlorine pairs are single-document, and 93% of them show stronger block, median +0.56 (3.6-fold), maximum +2.12. For hERG "stronger" is worse: this is the antitarget, and a chlorine reliably makes it worse while a fluorine on the same channel does nothing (median 0.00 over 91 pairs). That is the lipophilicity story in one row (a chlorine adds roughly 0.7 to logP, a fluorine about 0.14), and it is now measured inside single documents rather than across them. AChE's chlorine behaves the same way (+0.30 over 107 pairs, 71% improved), which I would read as a series effect rather than a class rule; the other five targets sit between −0.11 and +0.05.
Two honest notes on the method. Reading inside one document does not always shrink a difference. For hERG's fluorines the largest within-document move (+3.46) is bigger than anything the database-wide comparison showed (+2.92), and CA II's chlorine goes from 4 tenfold-plus moves to 6. The rule changes which two numbers you compare; it is not a smoothing filter. And where several documents report both compounds, this takes the middle document's answer, not the most dramatic one. For an effect size that is the right choice; for hunting cliffs it would not be.
How this was answered
Try next
Example 4.3 applies the same rule to activity cliffs, where it removes a third of the list rather than 6%.
Figure 1: One fluorine, one methyl, one chlorine: only the pairs measured in one document. Each dot is one matched molecular pair among the 1,500 most potent ligands of that target: two compounds differing only by the marked group, placed at the change in potency the group brought. Blue pairs have both values in a single patent or paper under one assay name and are plotted from that document's own two values; grey pairs have no document in common and are shown where the database-wide best values put them. The bar is the median of the blue pairs, and the dashed line is no change.
👤 User
What did the rule cost me on each target, and which of these targets can I trust it on at all?
🧠 Assistant
It cost very little almost everywhere, and a lot on exactly one target. Of the 1,686 pairs, 102 had no document reporting both compounds under one assay (the grey dots in the figure above), and 42 of those 102 belong to AChE.
| Target | Pairs | Readable inside one document | Documents behind them | Most prolific document |
|---|---|---|---|---|
| Adenosine A2A | 236 | 235 (100%) | 51 (40 papers, 11 patents) | US20230293517-A1, 25 pairs |
| ROR-γ | 252 | 249 (99%) | 33 (12 papers, 21 patents) | US9663502-B2, 61 pairs |
| CA II | 167 | 161 (96%) | 55 (all papers) | PMID 33121862, 18 pairs |
| hERG | 248 | 234 (94%) | 45 (38 papers, 7 patents) | US9981950-B2, 48 pairs |
| EGFR | 168 | 156 (93%) | 46 (35 papers, 11 patents) | US11066414-B2, 61 pairs |
| BACE1 | 341 | 317 (93%) | 49 (30 papers, 19 patents) | US20160046618-A1, 141 pairs |
| AChE | 274 | 232 (85%) | 60 (58 papers, 2 patents) | PMID 39673864, 24 pairs |
The split by assay name inside a document cost almost nothing: 12 pairs in total, out of 1,596 that share a document. Patents and papers that report two analogues usually report them in the same table under one protocol; it is worth insisting on, but it is not where the losses are.
Three targets you can lean on. Adenosine A2A (235 of 236), ROR-γ (249 of 252) and CA II (161 of 167) lose essentially nothing, and all three give a flat answer for every substituent: nine medians, all between −0.05 and +0.05. Those flat numbers are now worth something, because they are not flat merely from mixing laboratories.
AChE is the one to distrust, and it is the one with the most interesting-looking result. Its fluorine pairs are only 72% checkable (26 of 36), and the 10 discarded pairs carry 5 of the 11 tenfold-plus moves; its methyl loses 19 of 118 and its chlorine 13 of 120. Its ligands come from the academic literature almost exclusively (225 of its 232 checked pairs sit in a paper, and only one of its 125 checked fluorine and methyl pairs in a patent) and they are spread over 60 documents, none contributing more than 24 pairs, so a matched pair often links two different research groups' compounds. Its chlorine signal (+0.30 over 107 pairs, 71% improved) survives the check, but 27 of those pairs still move potency more than tenfold: that is a target where a chlorine sometimes matters enormously and sometimes not at all, not a target with a reliable chlorine increment. Being article-based is not itself the problem: CA II is 100% article and 96% checkable. The problem is a crowded literature of close analogues published separately.
Two targets that are checkable but not independent. BACE1 keeps 93% of its pairs, but 141 of its 317 come from one patent's FRET assay, and EGFR has 61 of 156 in one patent's high-throughput assay. Across all seven targets the 1,584 checked pairs rest on 338 documents and 362 document-and-assay combinations, and the five biggest of those carry 341 pairs between them. The rule guarantees the two numbers in a pair are comparable; it does not guarantee that 300 pairs are 300 independent observations. For BACE1 the fluorine result (+0.09, 62% improved, 192 pairs) is largely one company's series, so read it as "a fluorine helped in this chemotype" rather than as a property of aspartyl proteases.
What the rule actually changed. Nowhere did a median move by more than 0.13 log units: AChE's fluorine (+0.08 → +0.21) is the largest shift on the board, BACE1's methyl (−0.11 → −0.02) the next. The rule buys confidence and tail discipline, not a different central answer: tenfold-plus moves fall from 11 to 4 on AChE's fluorine, 15 to 9 on its methyl, 33 to 27 on its chlorine, 2 to 0 on EGFR's fluorine. On CA II's chlorine it goes the other way, 4 to 6, because within-document comparisons can be sharper than the cross-document ones they replace.
How this was answered
Try next
Example 3.4 drills into a single measurement, assay text and all, when you want to see what one of these documents actually reports.